General Chat
OAE Agent
Doc Retrieval
Doc Agent
Doc Agent
Doc Agent
This Ai is very simmilar to Doc Retrival, but it does better with meta conversations and stores conversations in memory
Summaries of Noise Regulations and Provisions MC 313 Section MC 313 outlines noise control and vibration isolation requirements: - General compliance for all interior and exterior mechanical equipment and systems. - Specific noise limits for equipment located outside or open to the exterior, with additional design and operational standards. - Detailed specifications for different types of equipment like boilers, refuse chutes, and mechanical systems for vibration isolation. - Design and installation requirements to comply with noise control codes. - Operation of equipment must also comply with relevant noise control codes. Lower Concourse Rezoning and Related Actions EIS The document discusses the assessment of noise impacts associated with a proposed rezoning in New York City: - Expected conversion from industrial to residential/commercial spaces with 'E' designations for noise mitigation. - Noise assessment evaluates the impact on existing and future sensitive locations due to increased traffic. - Specific noise level measurements and mitigation measures are detailed to maintain a comfortable sound environment. AC 24-218 Section 24-218 addresses general prohibitions against unnecessary noise in New York City: - Prohibits unnecessary noise exceeding specific decibel levels, particularly during night-time. - Defines unreasonable noise with specific dB(A) thresholds. - Provides exceptions and specific regulations for construction noise and refuse collection facility noise. 24-227 Section 24-227 sets regulations for the operation of circulation devices, typically HVAC systems: - Limits sound levels within residential and mixed-use buildings. - Specifies a post-effective date sound limit for new installations or replacements. - Offers a two-year exemption period for replacements of devices installed prior to the section's effective date. 24-228 Section 24-228 regulates noise control for construction and mechanical exhausts: - Limits on construction noise and specific decibel thresholds for devices. - Prohibits exhaust discharges that create unreasonable noise as per specified levels. - Requires compliance with specific decibel limits for all construction-related noise. 24-232 Section 24-232 provides decibel level limits across various frequency bands for sound sources from commercial/business enterprises: - Specifies decibel limits for different octave bands. - Requires compliance with these limits and additional codes. - Measurements should not be taken in non-living areas. - Lists exemptions for impulsive sounds, existing utility structures, and refuse collection facilities. ```
Loading...
Upload
Show intermediate steps
Loading...
Send